GLVAC, JPK Cross Reference

Products And Services

Your Position:Home > Products and Services > Vacuum Relay

Update Time:2013-12-08GLVAC, JPK Cross Reference

<
>

Product Name:Vacuum Relay

Item No:GL8

Description:
  • Durable tungsten contacts for hot load switching
  • Vacuum dielectric for effective arc quenching when opening under load
  • Two mounting styles available, flange or through panel with jam nut.
  • Solder or threaded high voltage connections help make installation easy.
  • User interchangeable coils provide for driver versatility
  • Meets or exceeds standards set in MIL-R-83725
  • Consult factory for load switching applications 


DownLoad GL8

GL8 Product Introduce


COIL RATINGS

Nominal, Volts dc
12
26.5
115
Pick-up, Volts dc, Max
8
16
80
Drop-Out, Volts dc
.5-5
1-10
5-50
Coil Resistance(Ω±10%)
48
180
3500
* Ratings listed are for 25°C, sea level conditions

Product Specifications

Contact & Relay Ratings
Units
GL8
Contact Form
C
Contact Arrangement
SPDT
Test Voltag,(kV, Peak), Test Max., Contacts & to Base (15 μA Leakage Max., dc or 60Hz)
KV Peak
17
Rated Operating Voltage,(kV,Peak), Contacts & to Base (15 μA Leakage Max.)
dc or 60Hz

KV Peak

15
2.5MHz
Kv Peak
-
16MHz
KV Peak
-
32MHz
KV Peak
-
Continuous Current, Carry Max
dc or 60Hz
Amps
30
2.5MHz
Amps
-
16MHz
Amps
-
32MHz
Amps
-
Coil Hi-Pot (V RMS, 60 Hz)
V
500
Capacitance
Across Open Contacts
pF
0.5
Contacts to Ground
pF
1
Resistance, Contact Max @ 1A, 28Vdc
ohms
0.025
Operate Time, Max
ms
15
Release Time, Max
ms
9
Mechanical Life
Cycles
1 million
Weight
g(02)
84(3)
Vibration, Sine (10-2000 Hz Peak)
G's
10
Shock, 1/2 Sine11ms (Peak)
G's
50
Operating Temperature Ambient
°C
-55 ~ +125



*Order the relay with the coil voltage in the part number as shown above. The coil voltage will appear on the coil plate near the coil terminals rather than in the P/N on the relay.