Product Name:Vacuum Relay

Item No:GL43C

Description:

Slim design is extremely space efficient in multi-relay applications
RF efficient design offers high power handling in a small package
Durable tungsten contacts for hot load switching
Vacuum dielectric for effective arc quenching when opening under load
Can be mounted and used in any position
Meets or exceeds standards set in MIL-R-83725
Consult factory for load switching applications

DownLoad GL43C

GL43C Product Introduce

Model
Specification
Contact & Relay Ratings Units GL43A

GL43B

GL43C
Contact Form A B C
Contact Arrangement SPDT -NO SPDT-NC SPDT
Test Voltag,(kV, Peak), Test Max., Contacts & to Base (15 μA Leakage Max., dc or 60Hz) KV Peak 11 11 11
Rated Operating Voltage,(kV,Peak), Contacts & to Base (15 μA Leakage Max.) dc or 60Hz

KV Peak

10 10 10
2.5MHz Kv Peak 7 7 7
16MHz KV Peak 6 6 6
32MHz KV Peak 4 4 4
Continuous Current, Carry Max dc or 60Hz Amps 25 25 25
2.5MHz Amps 20 20 20
16MHz Amps 13 13 13
32MHz Amps 10 10 10
Coil Hi-Pot (V RMS, 60 Hz) V 500 500 500
Capacitance Across Open Contacts pF 1.2 1.2 1.2
Contacts to Ground pF 1.2 1.2 1.2
Resistance, Contact Max @ 1A, 28Vdc ohms 0.02 0.02 0.02
Operate Time, Max ms 10 10 10
Release Time, Max ms 10 10 10
Mechanical Life Cycles 2 million 2 million 2 million
Weight g(02) 28(1) 28(1) 28(1)
Vibration, Sine (10-2000 Hz Peak) G's 10 10 10
Shock, 1/2 Sine11ms (Peak) G's 50 50 50
Operating Temperature Ambient °C -55 ~ +125 -55 ~ +125 -55 ~ +125

Coil Ratings
Coil Ratings
Nominal, Volts dc 12 26.5 115
Pick-up, Volts dc, Max 8 16 80
Drop-Out, Volts dc .5-5 1-10 5-50
Coil Resistance(Ω±10%) 70 290 4700
* Ratings listed are for 25°C, sea level conditions

* Order the relay with the coil voltage in the part number as shown above. The coil voltage will appear on the coil plate near the coil terminals rather than in the P/N on the relay.