GLVAC, Jennings Cross Reference

Products And Services

Your Position:Home > Products and Services > Vacuum Relay

Update Time:2013-12-08GLVAC, Jennings Cross Reference

<
>

Product Name:Vacuum Relay

Item No:GL41A

Description:

Slim design is extremely space efficient in multi-relay applications
RF efficient design offers high power handling in a small package
Durable tungsten contacts for hot load switching
Vacuum dielectric for effective arc quenching when opening under load
Can be mounted and used in any position
Meets or exceeds standards set in MIL-R-83725
Consult factory for load switching applications

DownLoad GL41A

GL41A Product Introduce

Model

Specification

Contact & Relay Ratings Units GL41A

GL41B

GL41C
Contact Form A B C
Contact Arrangement SPDT -NO SPDT-NC SPDT
Test Voltag,(kV, Peak), Test Max., Contacts & to Base (15 μA Leakage Max., dc or 60Hz) KV Peak 6 6 6
Rated Operating Voltage,(kV,Peak), Contacts & to Base (15 μA Leakage Max.) dc or 60Hz

KV Peak

5 5 5
2.5MHz Kv Peak 4.5 4.5 4.5
16MHz KV Peak 3.5 3.5 3.5
32MHz KV Peak 2.8 2.8 2.8
Continuous Current, Carry Max dc or 60Hz Amps 30 30 30
2.5MHz Amps 24 24 24
16MHz Amps 16 16 16
32MHz Amps 12 12 12
Coil Hi-Pot (V RMS, 60 Hz) V 500 500 500
Capacitance Across Open Contacts pF 1.2 1.2 1.2
Contacts to Ground pF 1.2 1.2 1.2
Resistance, Contact Max @ 1A, 28Vdc ohms 0.02 0.02 0.02
Operate Time, Max ms 10 10 10
Release Time, Max ms 10 10 10
Mechanical Life Cycles 2 million 2 million 2 million
Weight g(02) 28(1) 28(1) 28(1)
Vibration, Sine (10-2000 Hz Peak) G's 10 10 10
Shock, 1/2 Sine11ms (Peak) G's 50 50 50
Operating Temperature Ambient °C -55 ~ +125 -55 ~ +125 -55 ~ +125

Coil Ratings
Coil Ratings
Nominal, Volts dc 12 26.5 115
Pick-up, Volts dc, Max 8 16 80
Drop-Out, Volts dc .5-5 1-10 5-50
Coil Resistance(Ω±10%) 80 330 6000
* Ratings listed are for 25°C, sea level conditions
* Order the relay with the coil voltage in the part number as shown above. The coil voltage will appear on the coil plate near the coil terminals rather than in the P/N on the relay.