Vacuum Relays

Products And Services

Your Position:Home > Products and Services > Vacuum Relay

Update Time:2013-11-25Vacuum Relays

<
>

Product Name:Vacuum Relay

Item No:GL2

Description:
    • High carry current, 50Adc continuous, in a small package
    • Low, stable contact resistance minimizes loss in RF circuits
    • Two mounting styles available, flange or through panel with jam nut.
    • Solder or threaded high voltage connections help make installation easy.
    • User interchangeable coils provide for driver versatility
    • Meets or exceeds standards set in MIL-R-83725
    • Consult factory for load switching applications 

DownLoad GL2

GL2 Product Introduce

Model

COIL RATINGS

Nominal, Volts dc
12
26.5
115
Pick-up, Volts dc, Max
8
16
80
Drop-Out, Volts dc
.5-5
1-10
5-50
Coil Resistance(Ω±10%)
60
250
3500
* Ratings listed are for 25°C, sea level conditions

Product Specifications

Contact & Relay Ratings
Units
GL2
Contact Form
C
Contact Arrangement
SPDT
Test Voltag,(kV, Peak), Test Max., Contacts & to Base (15 μA Leakage Max., dc or 60Hz)
KV Peak
17
Rated Operating Voltage,(kV,Peak), Contacts & to Base (15 μA Leakage Max.)
dc or 60Hz

KV Peak

15
2.5MHz
Kv Peak
12
16MHz
KV Peak
9
32MHz
KV Peak
7
Continuous Current, Carry Max
dc or 60Hz
Amps
50
2.5MHz
Amps
30
16MHz
Amps
17
32MHz
Amps
10
Coil Hi-Pot (V RMS, 60 Hz)
V
500
Capacitance
Across Open Contacts
pF
0.5
Contacts to Ground
pF
1
Resistance, Contact Max @ 1A, 28Vdc
ohms
0.012
Operate Time, Max
ms
15
Release Time, Max
ms
9
Mechanical Life
Cycles
1 million
Weight
g(02)
84(3)
Vibration, Sine (10-2000 Hz Peak)
G's
10
Shock, 1/2 Sine11ms (Peak)
G's
50
Operating Temperature Ambient
°C
-55 ~ +125


* Order the relay with the coil voltage in the part number as shown above. The coil voltage will appear on the coil plate near the coil terminals rather than in the P/N on the relay.