Gas-Filled Relays

Products And Services

Your Position:Home > Products and Services > Gas-filled Relay

Update Time:2013-11-25Gas-Filled Relays

<
>

Product Name:Gas-filled Relay

Item No:GL13

Description:

FEATURES

  • 2 pole, Double Throw for switching between and/or reversing power sources or loads.
  • Completely sealed for years of failure free operation.
  • SF6 gas filled for high energy in-rush switching.*
  • Insulated flying leads make connection easy. Custom lengths available.
  • Not position sensitive allowing mounting flexibility.
  • Threaded base and top tabs provide mounting flexibility.
  • *Consult factory for load switching applications.

DownLoad GL13

GL13 Product Introduce


Nominal, Volts dc
12
26.5
115
Pick-up, Volts dc, Max.
8
16
80
Drop-Out, Volts dc
.5 - 5
1 - 10
5 - 50
Coil Resistance (Ohms ±10%)
48
180
2900

For more information, refer to
Relay User Instructions
For more information, refer to
Relay User Instructions
Contact & Relay Ratings
Units
G13
Contact Form
2C
Contact Arrangement
DPDT
Voltage, Test Max., Contacts & to
Base (15 µA Leakage Max., dc or 60Hz)
kV Peak
17
Voltage, Operating Max., Contacts & to
Base (15 µA Leakage Max.)
dc or 60 Hz
kV Peak
15
2.5 MHz
kV Peak
-
16 MHz
kV Peak
-
32 MHz
kV Peak
-
Current, Continuous Carry Max
dc or 60 Hz
Amps
10
2.5 MHz
Amps
-
16 MHz
Amps
-
32 MHz
Amps
-
Coil Hi-Pot (V RMS, 60 Hz)
V
500
Capacitance
Across Open Contacts
pF
0.5
Contacts to Ground
pF
1
Resistance, Contact Max @ 1A, 28 Vdc
ohms
1.0
Operate Time
ms
15
Release Time
ms
9
Life, Mechanical
cycles
1 million
Weight, Nominal
g (oz)
140 (5)
Vibration, Operating, Sine (55-500 Hz Peak)
G's
10
Shock, Operating, 1/2 Sine11ms (Peak)
G's
50
Temperature Ambient Operating
°C
-55 to +85
G13 - 12Vdc
Coil Voltage*
Blank = 26.5 Vdc
12Vdc = 12 Vdc 
115Vdc = 115 Vdc


COIL RATINGS

Ratings listed are for 25°C, sea level conditions 

Product Specifications


*Order the relay with the coil voltage in the part number as shown above. The coil voltage will appear on the coil plate near the coil terminals rather than in the P/N on the relay.