Gas-Filled Relays

Products And Services

Your Position:Home > Products and Services > Gas-filled Relay

Update Time:2013-11-25Gas-Filled Relays

<
>

Product Name:Gas-filled Relay

Item No:GL15

Description:

    • Durable tungsten contacts for hot load switching
    • Vacuum dielectric for effective arc quenching when opening under load
    • Two mounting styles available, flange or through panel with jam nut.
    • Solder or threaded high voltage connections help make installation easy.
    • User interchangeable coils provide for driver versatility
    • Meets or exceeds standards set in MIL-R-83725
    • Consult factory for load switching applications 

DownLoad GL15

GL15 Product Introduce


Model

COIL RATINGS

Nominal, Volts dc
12
26.5
115
Pick-up, Volts dc, Max
8
16
80
Drop-Out, Volts dc
.5-5
1-10
5-50
Coil Resistance(Ω±10%)
48
180
2900
* Ratings listed are for 25°C, sea level conditions

Product Specifications

Contact & Relay Ratings Units GL15
Contact Form C
Contact Arrangement SPDT
Test Voltag,(kV, Peak), Test Max., Contacts & to Base (15 μA Leakage Max., dc or 60Hz) KV Peak 17
Rated Operating Voltage,(kV,Peak), Contacts & to Base (15 μA Leakage Max.) dc or 60Hz

KV Peak

15
2.5MHz Kv Peak -
16MHz KV Peak -
32MHz KV Peak -
Continuous Current, Carry Max dc or 60Hz Amps 12
2.5MHz Amps -
16MHz Amps -
32MHz Amps -
Coil Hi-Pot (V RMS, 60 Hz) V 500
Capacitance Across Open Contacts pF 0.5
Contacts to Ground pF 1
Resistance, Contact Max @ 1A, 28Vdc ohms 1.0
Operate Time, Max ms 15
Release Time, Max ms 9
Mechanical Life Cycles 1 million
Weight g(02) 84(3)
Vibration, Sine (10-2000 Hz Peak) G's 10
Shock, 1/2 Sine11ms (Peak) G's 50
Operating Temperature Ambient �C -55 ~ +125


* Order the relay with the coil voltage in the part number as shown above. The coil voltage will appear on the coil plate near the coil terminals rather than in the P/N on the relay.