SPDT Relays

Products And Services

Your Position:Home > Products and Services > SPDT Relay

Update Time:2013-11-25SPDT Relays

<
>

Product Name:SPDT Relay

Item No:GL10

Description:
  • Load switch
  • Vacuum as dielectric , low contact resistance
  • Meets or exceeds MIL-R-83725

DownLoad GL10

GL10 Product Introduce

Model


Nominal, Volts dc
12
24
26.5
Pick-up, Volts dc, Max.
8
16
16
VdcDrop-Out, Volts dc
.5-5
1-10
1-10
Coil Resistance 
(Ohms ±10%)
48
190
190
* Ratings listed are for 25°C, sea level conditions
Relay User Instructions 
Contact & Relay Ratings Units GL10WF
Contact Form C
Contact Arrangement SPDT
Voltage, Test Max., Contacts & to 
Base (15 μA Leakage Max., dc or 60Hz)
KV Peak 22
Voltage, Operating Max., Contacts & to 
Base (15 μA Leakage Max.)
dc or 60Hz

KV Peak

20
2.5MHz Kv Peak -
16MHz KV Peak -
32MHz KV Peak -
Current, Continuous Carry Max dc or 60Hz Amps 45
2.5MHz Amps -
16MHz Amps -
32MHz Amps -
Coil Hi-Pot (V RMS, 60 Hz) V 500
Capacitance Across Open Contacts pF 3
Contacts to Ground pF 3.5
Resistance, Contact Max @ 1A, 28Vdc ohms 0.02
Operate Time ms 30
Release Time ms 8
Life, Mechanical Cycles 1million
Weight, Nominal g 300
Vibration, Operating, Sine (10-2000 Hz Peak) G's 10
Shock, Operating, 1/2 Sine11ms (Peak) G's 50
Temperature Ambient Operating °C -55 ~ +125



COIL RATINGS

For more information, refer to

Product Specifications

* Order the relay with the coil voltage in the part number as shown above. The coil voltage will appear on the coil plate near the coil terminals rather than in the P/N on the relay.